Renice 3U Open VPX Storage Module

3U Open VPX Storage Module

Renice 3U Open VPX storage module is a networked storage product based on RapidIO and Ethernet interfaces. It is mainly composed of VPX connector, FPGA (embedded ARM processor), DDR memory, Ethernet controller, BMC, and 3x Renice industrial grade SATA SSDs. 3U Open VPX storage module has the characteristics of massive data storage, high speed data transmission, networked service and management, high reliability and can support data destruction. It is suitable solution for network storage servers and data centers in special fields such as industry and aviation.
Basic Information
Host InterfaceVPX, 20Gbps
Dimension157mm x 100mm x 26mm (LxWxH)
Form FactorVPX P0, P1, P2, P3, P4, P5, P6
Max Capacity6TB
Working Voltage12V
Power Consumption<=15W
System Configuration
ProcessorFPGA
Memory2GB,DDR3
Storage3TB (standard), max up to 6TB
Hard Disk Interface3x SATAIII
Read/Read Speed>=400MB/s
Realtime Bus Interface1x RapidIO(X4, 5Gbps*4)
Ethernet Interface1x 10/100/1000M (serdes interface)
State Monitoring Interface1x RS485, 2x IPMB, max support 1Mbps
Serial Interface1x RS-232 Debug UART, Baud Rate max support 115200. Communication between the FPGA and the BMC through the serial port.
RAID ModeRAID0, RAID1
Data DestructionLogical Destruction, destruction time<30s
SSD Specification
InterfaceSATA III
Capacity256GB~2TB (MLC SSD); 128GB~1TB (SLC SSD)
SMART√
Power-off Protection√
ECC80bit/1KB
Wear LevelingRenice® Non-Balance Wear Leveling
Write Endurance>25 years @ 100GB per day erase (512GB MLC)
Chip Reinforcement√(under-fill glue)
Conformal Coating√
Software Specification
OSEmbedded OS
Starting Time<=12s
Data Record ManagementEthernet and RapidIO based data record management
Network File ServiceSupport Ethernet file opening, deleting, closing, reading and writing, IoCtl and other network file service capabilities
Client Access ServiceEthernet based file open, delete, close, read and write operation, IoCtl and other network file operation functions, and provide API interface functions.
Address Configuration ManagementWith automatic identification and configuration function, the unit IP address and RapidIO address can be automatically generated and set according to the chassis ID, slot ID and module type.
State Monitoring ManagementBMC provides hardware monitoring protection, module switch control, processor running state monitoring and other functions. BMC can communicate with the processor and the firmware storage unit via local bus (serial port or LPC or I2C) to realize parameter transfer and local communication with the firmware.
Environment
Operation Temperature-43℃ to +65℃
Storage Temperature-50℃ to +70℃
Humidity95%
VibrationGJB150.16-1986 standard
ShockGJB150.18A-2009 standard